Ⅰ 、 Spesifikasi Teknis Utama
L pengukuran penyimpangan: ≤ ± 0,5%f · s ± 1
L Kompensasi Kompensasi Akhir Dingin: ≤ ± 2.0 ℃
l Siklus Pengambilan Sampel: 0,5S
l Siklus kontrol: output relai 2 ~ 120S, lainnya adalah 2s.
l relai output kapasitas kontak: AC250V/7A (beban resistansi) atau AC250V/0.3A (beban persepsi)
l Mengemudi output pulsa yang dapat dikendalikan: ≥3V lingkup, ≥40us lebar lebih dari nol atau pemicu pulsa kontak
l Mengemudi output sinyal relai padat: Mengemudi arus listrik ≥15mA, tegangan ≥9v.
l PID kontinu: 0 ~ 10mA (beban 500 ± 200Ω), 4 ~ 20mA (beban 250 ± 100Ω),
atau 0 ~ 5V (beban ≥100kΩ), 1 ~ 5V (beban ≥100kΩ)
l Catu Daya: AC85V ~ 242V, 50/60Hz
L Kondisi Kerja: Suhu 0 ~ 50.0 ℃, Kelembaban Relatif ≤85%RH, Tanpa Korosi dan Radiasi Listrik yang Kuat.
Ⅱ 、 Kode Produk:
Xmt □ 9 □ 8 □
(1) ⑵ (3) (4) (5)
(1) Dimensi Faceplate Meter
Blank: 160mm × 80mm x 120mm Instalasi Lubang: 152mm x 76mm
A: 96mm x 96mm x 110mm Instalasi Lubang: 92mm x 92mm
D: 72mm x 72mm x 110mm Lubang instalasi: 68mm x 68mm
E: 48mm x 96mm x 110mm Lubang Instalasi: 44mm x 92mm
F: 96mm x 48mm x 110mm Instalasi Lubang: 92mm x 44mm
S: 80mm x 160mm x 120mm Lubang Instalasi: 76mm x 156mm
G: 48mm x 48mm x 110mm Instalasi Lubang: 44mm x 44mm
(2) Desain nomor seri
(3) Alarm
“0”: tidak ada alarm “1or2”: satu alarm (batas atas, batas bawah) “5”: alarm suara
"3": dua alarm grup (batas atas, batas bawah, alarm penyimpangan positif dan pengaturan diskresi alarm deviasi negatif)
(4) Sinyal Input
"8": Pertukaran gratis dari sinyal input
⑸ Metode Kontrol
Blank: Kontak relay
"A": penyesuaian pemicu over-nol fase tunggal
"A3": Penyesuaian pemicu over-nol tiga fase
"B": Penyesuaian pemicu fase-fase-fase tunggal
"B3": Penyesuaian pemicu pemicu fase tiga fase
“C”: 0-10mA atau 4-20mA output arus listrik konstan
“G”: Solid State Relay (SSR) Output
Ⅲ 、 Instruksi Panel (Konsultasikan)
Ⅳ 、 mode pengaturan kode
Series |
Code |
Name |
Setting range |
Manual |
Remarks |
0 |
SP |
Appointed data |
Determined by P-SL P-SH |
- |
50.0 |
1 |
AL-1 |
Alarm 1 |
Determined by P-SL,P-SH when the upper and lower limit range,it is0~50.0 when the upper and lower limit deviation alarm |
Alarm 1 setting value |
10 |
2 |
AL-2 |
Alarm 2 |
Determined by P-SL,P-SH when the upper and lower limit range,it is0~50.0 when the upper and lower limit deviation alarm |
Alarm 1 setting value |
10 |
3 |
P |
Proportion modulus |
0~100 |
When the P↑,the the proportion function↓ When P=0,the meter is ON/OFF control |
8 |
4 |
I |
Calculus time |
0~2000S |
240 |
|
5 |
d |
differential time |
0~200S |
30 |
|
6 |
At |
Setting itself |
ON:open setting inself function OFF:close setting itself function |
Select of setting itself |
OFF |
7 |
t |
SSR proportion Control period |
1~120S |
the movements cycle ON/OFF of Setting relays control is no meaning |
20 |
8 |
Hy |
Main control by drop in level |
0.1~50.0 |
Only have meaning when main control output is ON/OFF(P=0) |
1.0 |
9 |
Hy-1 |
Alarm 1 drop in level |
0.1~50.0 |
It has use drop in level setting of alarm contact output |
1.0 |
10 |
Hy-2 |
Alarm 2 drop in level |
0.1~50.0 |
It has use dropin level setting of alarm contact output |
1.0 |
11 |
Pb |
Sensor error amendment |
±20.0 |
The sensor have deviation can use item to revisal |
0 |
12 |
FILT |
Filt modulus |
0~50 |
Is the software filter constants of measurement sampling.The constant ↑,the Measurements antijamming capabilityMeasurements antijamming capability↑,but the measurement and system time ↓ |
20 |
13 |
dp |
Show accuracy |
0~1 |
0: have radix point,1: have no radix point |
- |
14 |
P-SH |
Display the high limit |
P-SL~9999 |
Can set the high limit displaying input signal |
400 |
15 |
P-SL |
Display the low limit |
-1999~P-SH |
Can set the low limit displaying input signal |
0 |
16 |
OUTL |
Allow exports min value |
0~OUTH |
It will no role when highest outputlimit,,manual and position. |
200.0 |
17 |
OUTH |
Allow exports max value |
OUTL~200 |
It will no role when lowest outputlimit,,manual and position. |
0.0 |
18 |
ALP1 |
Alarm1 and output definition |
0~4 |
‘0’:indicate no alarm
‘1’:upper limit touch alarm ‘2’:lower limit touch alarm ‘3’:upper windage alarm ‘4’:lower windage alarm |
- |
19 |
ALP2 |
Alarm2 and output definition |
0~4 |
- |
|
20 |
COOL |
System function choice |
0~1 |
‘0’:reverse control ‘1’:positive control |
0 |
21 |
OPPO |
Open power output |
0~100 |
Soft start functionthat meters coefficient after first export of electric power |
0 |
22 |
LOCK |
Code lock |
0~50 |
0- all the parameter can be revised 1- only the sp can be revised |
0 |
23 |
Sn |
Input type |
0~70. |
0-CU50 (-50.0~150.0℃) ;1-PT1 (-200.0~200.0℃) ;2-PT2 (-200.0~600.0℃) ;3-K (0~1300℃) ;4-E (0~700.0℃) ;5-J (0~900.0℃) ;6-T (-200~400.0℃) ;7-S (0~1600℃) ; | |
24 |
OP-A |
Output type |
1~4 |
1- RLP SSR output mode 2- SSR solid state relay 3- Zero controllable silicon contact signal when it exceed zero output mode 4- Mut controllable silicon phase trigger contact output mode 5- 0~10MA linearity control electric current output 6- 4~20MA linearity control electric current output |
Ⅴ 、 indeks teknis
1 、 Area pengaturan pertama
Tekan tombol Set 3S masuk ke area pengaturan pertama, meter akan menampilkan kode parameter 1 ~ 24 di jendela di baris atas dan menampilkan data parameter di baris rendah. Pada saat ini tekan tombol ▲ 、 ▼ atau T untuk menyesuaikan parameter, lalu tekan tombol Set untuk melestarikan. Tekan tombol Set lama akan menarik atau tekan tombol + ƒ akan langsung menarik. Jika dalam 10 detik tidak menekan setiap tombol maka secara otomatis akan melestarikan data dan menarik pengaturan.
2 、 Area pengaturan kedua
Ketika meter diatur dengan listrik, tekan tombol set masuk ke area pengaturan kedua, Anda dapat sesuai 1 untuk mengatur "SP".
3 、 Peraturan Manual
Ketika meter diatur dengan listrik, tekan tombol T sekitar 3s masuk ke dalam regulasi manual, itu akan menampilkan "h" di baris bawah, pada saat ini dapat mengatur daya output; Tekan tombol T sekitar 3s lagi itu akan menarik peraturan manual.
Ⅵ 、 pengaturan itu sendiri
Penggunaan meter pada pertama kalinya atau sekitarnya memiliki pengubah, menemukan itu mengendalikan tidak baik, saat ini Anda perlu menggunakan pengaturan itu sendiri. Misalnya:
Set pertama AT = ON, AM Light berkedip, meter masuk ke pengaturan itu sendiri, tekan tombol Set Enter ke dalam pengaturan parameter. Atur HY adalah 0,5 ~ 1 ℃, jika output adalah Relai mengatur t = 2s, meter memiliki tiga kali bergetar, parameter P, I, D yang diawetkan secara otomatis, dan AT Light Off, pengaturan itu sendiri selesai.
Ⅶ 、 Skema Koneksi (Konsultasikan)
★ Komentar : Perusahaan kami akan meningkatkan teknologi produk 、 Desain dan spesifikasi , ini dikonfirmasi ke objek .。
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.